Share
The supply and exhaust unit Vents VUT 1000 VG with a water heater is a completely finished ventilation unit that provides filtration, supply of fresh air to the premises and removal of contaminated air. In this case, the heat of the exhaust air is transferred to the supply air through a plate recuperator; for additional heating, a water heater is used, to which hot water is supplied from the boiler. Nominal capacity1100 m3/h. The unit is designed for connection to round air ducts with a nominal diameter of 250 mm.
The unit is supplied with an automation system and is ready for operation. To regulate the water flow through the water heater, you can use the USVK mixing unit (supplied separately) or any other circulation pump with a three-way valve with the required characteristics.
House
The body is made of aluminum-zinc steel with internal heat and sound insulation made of 25 mm thick mineral wool.
Filter
To filter supply and exhaust air, the unit has two built-in filters with a cleaning degree of G4 (exhaust) and F7 (supply).
Fans
The units are equipped with supply and exhaust double-suction centrifugal fans with forward-curved blades and a built-in protection thermostat with automatic restart. Electric motors and impellers are dynamically balanced in two planes. Rolling ball bearings of electric motors do not require maintenance, the service life is at least 40,000 hours.
Recuperator
The installations use highly efficient cross-current recuperators made of aluminum plates. Under the recuperator block there is a tray for collecting and discharging condensate.
Heater
To operate the air handling unit at low outside temperatures, a water heater is installed. If using heat recovery it is not possible to achieve the set value of the supply air temperature, the heater automatically turns on and heats the air entering the room.
Control and automation
The installation is equipped with a built-in automation system and a multifunctional control panel with a graphic indicator. The standard installation kit includes a 10 m long wire for connecting to the remote control. To prevent the recuperator from freezing, electronic anti-freeze protection is used using a bypass and a heater. Its essence is that, based on the temperature sensor, the bypass damper opens and all the supply air passes past the recuperator through the bypass channel. During the defrosting period of the recuperator, the supply air is heated to the required temperature in the heater. During defrosting, warm exhaust air warms up the recuperator. Then the damper closes the bypass, the heater turns off, the supply air again passes and is heated through the recuperator, and the entire installation operates as usual.
Control and protection functions of VUT VG
- turning on and off the installation,
- control of the supply air temperature by influencing the drive of a three-way valve that regulates the supply coolant into the liquid heater,
- protection of the liquid heater from freezing (using the air temperature sensor after the heater and the return coolant temperature sensor),
- control of the electric drive of the recuperator bypass valve, < li> control and monitoring of the operation of an external circulation pump installed on the coolant supply line to the liquid heater,
- protection of the heat exchanger from icing,
- control and monitoring of the operation of the supply and exhaust fans,< /li>
- control of filter contamination (by the number of operating hours),
- control of electric drives of external air valves (supply and exhaust).
The air handling unit is equipped with a remote control a control panel that provides:
- turning on/off the ventilation unit,
- setting the required air flow rate,
- setting the required supply air temperature,
- display of room temperature.
Installation
The air handling unit is mounted on the floor, suspended from the ceiling using a mounting bracket with a vibration insert, or mounted on the wall using brackets. The installation can be placed both in auxiliary rooms and in the main ones (behind a suspended ceiling, in a niche or in an open way). It can only be installed in such a position as to ensure collection and drainage of condensate. Access for service and filter cleaning is from the side panels.
Specifications
| Parameter | Value |
| Voltage, V | 230 |
| Current frequency, Hz | 50 |
| Maximum fan power, W td> | 2x410 |
| Total power of the installation, W td> | 820 |
| Total current, A | 3.6 |
| Productivity, m3/h br> | 1100 | tr>
| Rotation speed, min-1 | 1850 |
| Noise level at a distance of 3 m, dB(A) | 60 |
| Maximum temperature of transported air, C < /td> | -25....+40 |
| Weight, kg | 88 |
| < strong>Size of connected air duct, mm | 250 |
Dimensions
| Dimensions | D | B | B1 | B2 | B3 | H td> | H1 | H2 | H3 | L | L1 | L2 |
| mm | 249 | 613 | 460 | 306 | 386 | 698 | 832 | 154 | 280 | 1071 | 1117 | 1171 |
Diagram
Documentation
VUT VG installation passport
Manual for the air handling unit automation system
| Characteristic | |
| Type of heater | Water |
| Efficiency | 1100 cubic meters/hour |
| Duct diameter | 250 mm |
Payment terms and order preparation
At DOMIS.PRO, we offer different payment terms depending on the product type, its availability and the characteristics of each order.
Different payment arrangements may apply to products in stock, made-to-order items and custom-manufactured products.
Any required deposit, payment deadlines and preparation or manufacturing conditions will be communicated to the customer before the order is confirmed and stated in the quotation or relevant contractual documentation.
Payment methods
Available payment methods may include:
- Bizum.
- Apple Pay.
- Visa and Mastercard bank cards.
- SEPA bank transfer.
- International SWIFT bank transfer.
The availability of each payment method will be indicated during checkout or in the relevant quotation.
Bank transfer details
Beneficiary: Domis Iberica Pro S.L.
NIF: B16460271
VAT identification number: ESB16460271
The bank details required to make a transfer will be provided on the invoice, quotation or order confirmation.
We recommend including the order number or quotation reference in the payment description.
VAT and invoicing
Prices and taxes are applied in accordance with current tax legislation.
Certain intra-Community supplies and exports outside the European Union may be exempt from Spanish VAT when legal requirements are met and supporting documentation is available.
Delivery outside Spain does not automatically qualify for VAT exemption. The applicable tax treatment will be determined before the order is confirmed.
Delivery and transport
Products may be delivered using DOMIS.PRO's own transport or through specialised transport companies and logistics operators.
Shipping costs, delivery times and transport conditions depend on the destination, product availability, dimensions, weight and characteristics.
This information will be communicated to the customer before order confirmation or included in the relevant quotation.
Bulky products and special deliveries
Some products, such as large-format SPC and WPC decorative panels, profiles, windows, doors and pergolas, may require specialised transport or specific unloading arrangements.
Where additional services are required, such as lifting equipment, special unloading or access by specific vehicles, the conditions and costs will be communicated to the customer in advance.
Order collection
Collection of products from our premises may be arranged when this option is available and has been confirmed in advance by DOMIS.PRO.
The collection location, date and time will be agreed before handover.
Payment and delivery enquiries
If you need information about payment terms, availability, transport or product delivery, please contact our team.
Domis Iberica Pro S.L.
NIF: B16460271
Address: Av. de la Pau 45, puerta 24B, 46730 Gandia, Valencia, Spain.
Email: info@domis.pro