Order Fire-retardant fire damper FPD-120-300x200-O-M-220-T-2F with electric drive 220v in Valencia at a great price
FPD VALVE
1. Valve designation
2. Fire resistance limit in minutes (60, 90, 120
minutes)
3. Valve cross-section dimensions (mm.)
4. Functional purpose (O - normally
open, Z - normally closed)
5. Drive type (M-electromechanical)
6. Drive voltage (220V, 24V)
7. With temperature sensor (T)
8. Valve connection type (Fl-flange, Np-nipple)
General information
Produced with a fire resistance rating of 120 minutes. Fire resistance limit of the valve FPD-120
- in mode normally open (fire retardant) valve - EI 120
- in normally closed (smoke) valve mode - EI 120, E120 < /ul>
- a normally open (fire-retarding) valve closes in the event of a fire, blocking the spread of fire and combustion products through the ventilation ducts;
- a normally closed (smoke) valve opens in the event of a fire. It is used in supply and exhaust smoke ventilation systems.
Various modifications are available according to purpose
Design and materials
The valve body is made of galvanized steel from a European manufacturer. It has a high zinc content of 275 mg/m2, in while the traditional zinc content is no more than 140 mg/m2. The rotary vane uses fire-resistant material. Along the perimeter of the rotary vane there is a thermoactive seal, which expands under the influence of high temperatures and thereby ensures high tightness of the closed valve. Valve actuators are installed outside the body. Damper the valve automatically blocks the air flow by the return spring of the servo drive.
Application
Intended for installation in ventilation ducts, to prevent the spread of fire and combustion products from one room to another by covering air ducts in accordance with the relevant norms and standards. According to their functional purpose, they are used in accordance with the requirements of SNiP 2.04.05, DBN V. 1.1-7 in heating, ventilation and air conditioning systems in civil and industrial structures and buildings, in emergency smoke ventilation systems, for smoke removal in case of fire in order to ensure the evacuation of people from premises or structures at the initial stage of a fire that occurred in one of the premises.
The valves are allowed for operation in a non-aggressive environment with a temperature exceeding + 35°C and a relative humidity of up to 80% in rooms with an explosion-proof environment .
Design diagram of FPD rectangular cross-section
Fire damper EI15, EIЗ0, EI45, EI60, EI90, EI 120

Values of damper overhangs beyond the fire damper body
When designing ventilation systems, it is necessary to take into account the damper overhang. Before and after the valve, it is necessary to design a straight section of the air duct with a cross-section equal to the cross-section of the valve, and a length equal to the damper overhang. FPD valves, which do not have an X2 blade overhang (up to B < 500 mm.), can be equipped with a protective mesh and used for shaft installation.
Type sizes and open cross-sectional area of valves, m2

Fire-retardant fire damper FPD-120-300x200-O-M-220-T-2F with electric drive 220v — design, delivery, installation
Fire-retardant fire damper FPD-120-300x200-O-M-220-T-2F with electric drive 220v — order with delivery | Domis.pro Valencia, Spain
| Characteristic | |
| The size of the rectangular channel | 400x200 mm |
The product will be manufactured after making a payment or a 50% advance payment.
Online payment methods: Bizum, Apple Pay, Mastercard, Visa.
For payments to the bank account of VIP Ventanas SL company: SWIFT, SEPA.
It is possible to make the payment without VAT if the product is delivered outside of Spain.
Delivery is carried out by the company's own transportation or delivery service.