Why buy from us?
Lorem Ipsum is simply dummy text of the printing and typesetting industry.
Ask a Question About This Product
- Availability: 99
- Brand: Vents
- Model: 9385
- Weight: 50.00kg
- UPC: 9385
- JAN: 732
Before placing an order, contact DOMIS.PRO to confirm delivery availability and arrangements for your chosen product, including the destination, delivery method, cost and timing.
For questions about returns or exchanges, contact DOMIS.PRO. Provide your order number and the product name so we can discuss your situation and the next steps.
Before ordering, check the specifications, dimensions and compatibility of the chosen product with your equipment or project.
If the product page does not provide enough information, ask DOMIS.PRO and include the model or product code. Confirm the supplied components and any specifications that matter to you before placing an order.
The air supply unit Vents PA 02 V is a completely ready-made ventilation unit to ensure the supply of fresh air through a network of air ducts into the premises. The unit with a nominal capacity of 2350 m3/hcan be used for ventilation of private premises, such as a house, apartment, cottage, as well as for ventilation of office or industrial premises. Connects to air ducts with a cross-section of 500x300 mm.
A water heater is installed in the air heating unit, which requires a supply of hot water with the required parameters from an external source (usually a boiler). To regulate the water flow through the heater, it is sometimes necessary to use a mixing unit, which is purchased separately.
Case
The body of the installation is made of aluminum-zinc. Sound insulation and thermal insulation are achieved through the use of a 50 mm thick layer of mineral wool.
Filter
A filter with replaceable inserts is used to filter the outside air in the unit. Filtration class - G4.
Heater
PA units are equipped with water heaters. There are two-row, three-row or four-row versions.
Fan
The units are equipped with a high-pressure frameless radial fan directly driven by an electric motor with an external rotor. The impeller blades are curved backwards. The fan provides optimal performance characteristics: air flow, noise level and efficiency. The fan can be easily removed from the housing for inspection and cleaning.
Installation
The Vents PA 02 V air supply unit is mounted on the floor, suspended from the ceiling using a mounting bracket with a vibration insert, or mounted on the wall using brackets. The installation can be placed both in auxiliary rooms and in the main ones (above a suspended ceiling, in a niche or in an open way). All electrical connections are made through the terminal block located in the junction box.
PA air handling units are equipped with brackets to facilitate installation of the unit. The unit can be mounted in any position, except vertical, when the air flow is directed downwards (heating elements should not be under the fan). It is necessary to provide the possibility of access to the unit in cases of servicing and cleaning the filter.
Control and automation
The unit comes with a built-in control and automation system that allows you to regulate the fan performance (3 speeds), set the supply air temperature, monitor the condition (degree of contamination) of the filter. In addition, the automation system provides active protection against overheating of the heater heating elements (for PA...E). The unit can be controlled from a distance using a remote control.
The remote control provides
- turning on/off the ventilation unit
- the ability to set the required air flow ,
- opportunity to set the desired supply air temperature,
- display of room temperature,
- display of a fault (emergency situation).
PA...V control and protection functions
For systems with a cooler, the automation panels are additionally equipped with a room temperature sensor-setter. The switchboard includes an electric drive for the air valve LF230. Heater piping components (pump, valve, three-way drive, etc.) are not included in the package.
Functionality
1. Automatic control of the supply air valve PPVA.
2. Monitoring and indication of filter contamination.
3. Smooth control of fan speed 3~380V (50Hz).
4 Maintaining a given supply air temperature or room temperature.
5. Control of a liquid air heater and monitoring its operation.
6. Control of a compressor-condensing unit (CCU) for systems with a cooler .
7. Exhaust fan start signal.
8. Possibility of individual configuration of all parameters of the ventilation system.
9. Stopping the system upon a signal from the fire alarm panel.
Specifications
| Parameter | Value |
| Voltage, V | 400 | tr>
| Current frequency, Hz | 50 |
| Maximum fan power, W | 620 |
| Fan current, A | 1.05 |
| Total power of the installation, W | 620 |
| Total current, A | 1.05 | Capacity, m3/h | 2350 |
| Rotation speed, min-1 | 2690 |
| Noise level at a distance of 3 m, dB(A) | 54 |
| Maximum temperature of transported air, C | -25....+45 | Weight, kg | 61 |
| Size of connected air duct, mm | 500х300 |
Dimensions

| Dimensions | B | B1 | B2 | B3 | H | H1 | H2 td> | L | L1 |
| mm | 500 | 520 | 689 | 646 | 300 | 320 | 447 | 1250 | 1212 td> |
Diagram

Documentation
Passport of the air handling unit with a water heater
Operation manual for installations with an automation system
| Characteristic | |
| Type of heater | Water |
| Efficiency | 2350 cubic meters/hour |
| The size of the rectangular channel | 500x300 mm |