Fan Vents 100 Style

'5

The Vents 100 Style exhaust fan is equipped with an automatically closing front panel. When the fan is turned off, the front panel of the fan smoothly closes and blocks the exhaust duct. Equipped with bearings, has a low noise level.

Technical characteristics of the fan

Parameter name Value
Maximum productivity, m3/h 97
Consumption, W 9
Voltage , V

220
Current consumption, A 0.059
Impeller rotation speed, min-1 2165
Sound pressure level at a distance of
3 m, dBA
< /br>
25
Weight, kg 0.55
Protection class IP 44
Pipe size, mm 100

Dimensions

'Dimensions

Dimensions

a b

c

d < /td> e
mm
175

221

77

99

39

Fan features

  • Used for exhaust ventilation of a bathroom, toilet, kitchen or other room.
  • The successful combination of the design of the fan housing, impeller and the use of bearings made it possible to achieve very quiet operation of the fan and reduce consumption per hour to 9 W.
  • When the fan is turned off, the exhaust duct is automatically closed. The front panel is equipped with a thermal actuator, which ensures smooth opening or closing.

'Front

  • The motor uses rolling bearings, which reduces the noise level, increases the reliability and service life of the hood.
  • The fan has a protection class of IP44, which allows it to be used in wet rooms. All electrical connections are protected by a sealed silicone cover
  • For service cleaning, the fan unit can be easily removed from the pipe, as shown in the figure below

'Construction'

Turning on and off

The fan can be turned on:

  • from a separate switch (not included in the delivery package)
  • together with lighting
  • from the RS-1-300 performance controller or the SPC-1 touch controller, which can also be used to regulate the hood’s performance. Using a regulator allows you to reduce the hood power and, at the same time, the noise level to a silent state.

All control devices are not included in the delivery package.

Connection diagram

'Connecting

Scheme for connecting the fan to an external separate switch or to a light switch.

Fan installation

The fan is designed for installation in the built-in exhaust duct of an apartment or house. Mounted directly with a pipe into the duct or through a small section of the air duct. The fan is axial and cannot be connected to a very long duct, this will reduce the performance and increase the noise level. The recommended length of the air duct is no more than 0.5 meters. It is also recommended to avoid turning the duct whenever possible, this will also affect performance and noise levels.

When installing the fan directly into an exhaust shaft, make sure that the fan pipe does not block the exhaust duct.

Warranty

The warranty for the Vents Style fan is 100 - 60 months (5 years) subject to compliance with the rules of transportation, storage, installation and operation. During this period, the manufacturer guarantees the normal operation of the equipment.

Documentation

You can download the passport, installation and operating instructions by clicking on the image below (pdf file 1.6 MB, will open in a new tab)

'User

Characteristic
Cord switch no
Timer no
Humidity sensor no
Efficiency 97 cubic meters/hour
Motion sensor no
Pipe diameter 100 mm

The product will be manufactured after making a payment or a 50% advance payment.

Online payment methods: Bizum, Apple Pay, Mastercard, Visa.

For payments to the bank account of VIP Ventanas SL company: SWIFT, SEPA.

It is possible to make the payment without VAT if the product is delivered outside of Spain.

Delivery is carried out by the company's own transportation or delivery service.

Write a review