Fan Vents 125 MA

Specifications

Parameter Value
Voltage, V

220
Maximum power consumption , Tue

18
Productivity, m3/h

185
Current, A 0.1
Rotation speed, min-1 2400
Noise level at a distance of 3 m, dB(A) 35
Weight, kg 0.75
Protection, class IP24
Pipe size, mm 125

Drawing and dimensions

'Drawing'

Dimensions ?D B B1 B2 H L L1
mm 125 190 174 128 173 98 33

Connection diagram

Connection diagram of a fan without a built-in switch to the network

'How

Application

  • Continuous or periodic exhaust ventilation of bathrooms, showers, kitchens and other domestic premises.
  • For installation in ventilation shafts or connections to air ducts.
  • Moving small and medium air flows over short distances with low resistance of the ventilation system.
  • For installation with 125 mm air ducts.

Design

  • Modern design and aesthetic appearance.
  • The housing and impeller are made of high-quality and durable ABS plastic , resistant to ultraviolet radiation.
  • The design of the impeller allows you to increase the efficiency of the fan and the service life of the motor.
  • The fan is equipped with a device that ensures smooth opening and closing of automatic shutters that prevent reverse draft.
  • Protection class IP 24.

Motor

  • Reliable motor with low energy consumption.
  • Designed for continuous operation and not requires maintenance.
  • Equipped with overheating protection.

Control

Manual:

  • The fan is controlled using a room light switch. The switch is not included in the delivery.
  • The fan is controlled via a built-in cord switch “B”. When the fan is mounted on the ceiling, this option is not used.
  • Speed control can be carried out using a thyristor regulator (see Electrical accessories). Fans can be connected several at a time to one control device.

Automatic:

  • Using an electronic control unit BU-1-60(see Electrical accessories). The control unit is supplied separately.
  • Using a timer “T” (the built-in adjustable shutdown delay timer allows the fan to operate for 2 to 30 minutes after it is stopped by the switch). li>
  • Using a humidity sensor and a timer “ТН” (if the humidity in the room exceeds the value set on the sensor of 60-90%, the fan will automatically turn on and continue operating until the humidity will return to normal, then the fan works out the time set on the timer and turns off).
  • Using a motion sensor and timer “TR” (if the sensor detects movement in its area of action, then the fan will automatically turn on and continue working on a timer from 2 to 30 minutes Detection range up to 4 meters (detection angle max. 100°).

Installation features

  • The fan is installed directly into the opening of the ventilation shaft.
  • When the ventilation shaft is located remotely, it is possible to use flexible air ducts. The air duct is connected to the fan outlet flange using a clamp.
  • Attached to the wall with screws.
  • Can be used for ceiling mounting.

Example installation

'Example

MA series fan data sheet

'Passport

Characteristic
Cord switch no
Timer no
Humidity sensor no
Efficiency 185 cubic meters/hour
Motion sensor no
Pipe diameter 125 mm

The product will be manufactured after making a payment or a 50% advance payment.

Online payment methods: Bizum, Apple Pay, Mastercard, Visa.

For payments to the bank account of VIP Ventanas SL company: SWIFT, SEPA.

It is possible to make the payment without VAT if the product is delivered outside of Spain.

Delivery is carried out by the company's own transportation or delivery service.

Write a review

Please login or register to review