Vents VUT 300-1 EG EC

The Vents VUT 300-1 EG EC unit is designed for supply and exhaust ventilation of residential or commercial premises. The supply and exhaust unit is capable of simultaneously supplying fresh air and removing exhaust air. The installation uses heat recovery and an electric heater with a capacity of3 kWto reheat the air. The productivity of this model is 300 m3/hwith a maximum pressure of 350 Pa. The fans of the unit use economical EC motors.

The delivery package includes an automatic control system for the ventilation unit, the unit is completely ready for operation. The diameter of the air ducts used is 150 mm, installation of the unit must be carried out in a closed room with a positive temperature.

House

The body is made of aluminum-zinc steel with internal heat and sound insulation made of 25 mm thick mineral wool.

Filter

To filter supply and exhaust air, the unit has two built-in filters with a cleaning degree of G4 (exhaust) and F7 (supply).

Fans

Uses highly efficient electronically commutated (EC) external rotor DC motors equipped with a double-inlet impeller with forward-curved blades. Such motors are by far the most advanced solution in the field of energy saving. EC motors are characterized by high performance and optimal control over the entire speed range. The undoubted advantage of an electronically commutated motor is its high efficiency (up to 90%).

Recuperator

Vents VUT 300-1 EG EC units use highly efficient recuperators (about 95%). In models VUT EG EC and VUT VG EC, counterflow recuperators are made of polystyrene. Under the recuperator block there is a tray for collecting and discharging condensate.

Heater

To operate the air handling unit at low outside temperatures, electric (for VUT EG EC models) or water (for VUT VG) heaters are installed. If using heat recovery it is not possible to achieve the set value of the supply air temperature, the heater automatically turns on and heats the air entering the room.

Control and automation

The installation is equipped with a built-in automation system and a multifunctional control panel with a graphic indicator. The standard installation kit includes a 10 m long wire for connecting to the remote control. To prevent the recuperator from freezing, electronic anti-freeze protection is used using a bypass and a heater. Its essence is that, based on the temperature sensor, the bypass damper opens and all the supply air passes past the recuperator through the bypass channel.

During the defrosting period of the recuperator, the supply air is heated to the required temperature in the heater. During defrosting, warm exhaust air warms up the recuperator. Then the damper closes the bypass, the heater turns off, the supply air again passes and is heated through the recuperator, and the entire installation operates as usual.

Control and protection functions of VUT EG EC

  • turning the unit on and off,
  • the ability to use the control panel to set the desired supply air temperature and maintain the set one,
  • the ability to use the control panel to regulate the fan rotation speed and, accordingly, change the performance of the installation,
  • the ability to control the electric drives of the air dampers,
  • when turning the installation on and off, the settings are processed necessary algorithms,
  • operation of the installation on a weekly timer,
  • active protection against overheating of the heater heating elements,
  • exclusion of the operation of the electric heater without turning on the fan,
  • two thermostats are installed to protect the electric heater from overheating,
  • the automation system is protected from short circuits by a circuit breaker,
  • the degree of filter clogging is controlled.

Supply supply - the exhaust unit is equipped with a remote control, which provides:

  • turning on/off the ventilation unit,
  • setting the required air flow,
  • setting the required supply air temperature air,
  • display of room temperature.

Installation

The air handling unit is mounted on the floor, suspended from the ceiling using a mounting bracket with a vibration insert or mounted on the wall using brackets. The installation can be placed both in auxiliary rooms and in the main ones (behind a suspended ceiling, in a niche or in an open way). It can only be installed in such a position as to ensure collection and drainage of condensate. Access for service and filter cleaning is from the side panels.

'Example

Technical characteristics

Parameter Value
Voltage, V
< /br>
230
Current frequency , Hz 50

Maximum fan power, W 2x70
Electric heater power, W

3000
Total power of the installation, W 3140
Total current, A 14 ,2
Productivity, m3/h

300

Rotation speed, min-1
< /br>
1380
Noise level at a distance of 3 m, dB(A)

24-45
Maximum temperature of transported air, C

-25....+60

Weight, kg 38
Size of connected air duct, mm

< /td>
150

Overall dimensions

'Dimensions

Dimensions D B B1 B2 B3 H H2 H3 L L1 L2
mm 149 500 403 161 249 555 127 231 1092 1137 1198

Diagram

'Air

Documentation

'Ventilation

Characteristic
Heater power 3 kW
Type of heater Electric
Efficiency 300 cubic meters/hour
Duct diameter 150 mm

The product will be manufactured after making a payment or a 50% advance payment.

Online payment methods: Bizum, Apple Pay, Mastercard, Visa.

For payments to the bank account of VIP Ventanas SL company: SWIFT, SEPA.

It is possible to make the payment without VAT if the product is delivered outside of Spain.

Delivery is carried out by the company's own transportation or delivery service.

Write a review

Please login or register to review