![Vents VUT 270 V5B EC Vents VUT 270 V5B EC](https://domis.pro/image/cache/catalog/i/gl/jg/212f0dc3350923c75e114fa99b8b95b3-550x550.png)
Share
The VUT 270 V5B EC air handling unit is made of polypropylene, which has high heat and sound insulation properties. Recovery efficiency from87 to 98%. The maximum output is300 m3/h. It is a ready-made ventilation unit with a control system for working together with the air duct system. The installation is characterized by low consumption, which does not exceed 162 W per hour, due to the use of an anti-freeze system and a polystyrene heat exchanger.
Technical characteristics h3>
Parameter | Value | ||
Voltage, V | 230 | tr>||
Current, A | 1.2 | ||
Current frequency, Hz | 50 | ||
Maximum power consumption, W | 162 | ||
Maximum productivity, m3/h | 300 | ||
Rotation speed, min -1 | 3200 | ||
Noise level at a distance of 3 m, dB(A) | 34 | ||
Maximum temperature of transported air, C | -25....+50 | ||
Heat recovery efficiency,% | up to 98 | ||
Size of connected air ducts , mm | 125 | ||
Weight, kg | 13.5 |
D | B | H | L |
125 | 590 | 893 | 316 |
Body
Installation body made of EPP foam polypropylene with a thickness of 15-26 mm, the material allows you to achieve high levels of thermal insulation and noise reduction efficiency.
Filtration
To filter supply and exhaust air, the unit uses two pocket filters with a cleaning degree of G4.
Fans
The fans use energy-efficient EC motors with low energy consumption. The total power consumption of the installation does not exceed 162 W per hour.
Recuperators
The installation uses a recuperator made of polystyrene. During the cold season, the heat from the exhaust air is transferred to the supply air, which reduces the load on heating the supply air.
The unit is equipped with a bypass damper for summer operation. In this mode, the air is directed bypassing the recuperator, while the temperature of the street air supplied to the premises does not change. In this modification, the damper is controlled manually.
Installation design
Control system
The unit is equipped with a built-in automation system and a touch wall panel control A14 with LED indication. The control panel is wall mounted.
To prevent the recuperator from freezing during the cold season, the unit is equipped with an active protection system. The temperature sensor stops the supply fan, while the warm exhaust air warms up the recuperators. The supply fan then turns on and the unit continues to operate as normal.
Thus, the supply air performance in the cold season will be lower due to periodic shutdown of the fan. This frost protection eliminates the need for an electric heater, resulting in low operating costs.
Operating modes
Using the control system of the air handling unit, you can perform the following actions:
- Turning the unit on/off,
- Selecting a performance mode within a range of fixed three speeds: minimum, medium and maximum.
- Selecting a performance mode from 0 to 100%
- Indication of the need to replace the filter.
- Failure indication
It is also possible to connect CO2 sensors, humidity sensors or any other sensor (relay input), the signal from which can switch the performance to maximum (All sensors are purchased separately and are not included in the delivery package) .
Installation
The installation is intended for installation in a room with positive temperatures. Can be installed on a balcony, pantry, basement, attic and other auxiliary rooms.
The installation requires condensate drainage. The hole for the drainage pipe is located at the bottom of the unit. Drainage must be diverted to the sewer system. If the drainage will be diverted to the street, it is necessary to provide heating for the drainage (not included in the delivery package). All drainage pipes must have a slope of at least 3°.
Working with software
This ventilation unit can be connected using USB cable to PC to change installation parameters settings.
Using the software you can change:
- each of the three preset speeds (minimum, average, maximum) in the range from 0 to 100%
- speed when a dry contact is closed (for connecting external devices) in the range from 0 to 100%
- frequency of the signal to replace (clean) the filter in the range from 0 to 10,000 operating hours
- humidity level of the connected external sensor (sensor purchased separately) from 30 to 80%
The software can be downloaded from the link (12.41 Mb, rar)
Diagram
Documentation
(pdf file, opens in a new tab) < /p>
Warranty
The manufacturer guarantees normal operation of the device fortwo yearsfrom the date of sale, subject to compliance with the rules of transportation, storage, installation and operation.
Characteristic | |
Efficiency | 300 cubic meters/hour |
Duct diameter | 125 mm |
The product will be manufactured after making a payment or a 50% advance payment.
Online payment methods: Bizum, Apple Pay, Mastercard, Visa.
For payments to the bank account of VIP Ventanas SL company: SWIFT, SEPA.
It is possible to make the payment without VAT if the product is delivered outside of Spain.
Delivery is carried out by the company's own transportation or delivery service.