Vents NK 600x300-15.0-3

The electric heater Vents NK 600x300-15.0-3 consists of a housing, a switching box and heating elements made of stainless steel, equipped with additional fins to increase the heat exchange area. NK duct heaters are equipped with two overheat protection thermostats:

  • main protection with automatic restart (triggered at temperatures above +50°C). After cooling, the thermostat automatically closes the heater control circuit.
  • emergency protection with manual restart (triggered at temperatures above +90°C). In the event of an alarm, power can only be supplied to the heater after a manual reset of the alarm.

For each standard size there are several power options. Greater power can be achieved by installing heaters in series one after another.

Installation

The heater is installed using a flange connection. The direction of air movement must correspond to the arrow on the heater. Duct heaters can be installed in any position, except for the position with the electrical panel at the bottom (the danger of condensation flowing in and short-circuiting the electrical wiring). It is recommended that they be installed so that the air flow is evenly distributed over the entire cross-section. An air filter must be installed in front of the heater to protect the heating elements from contamination.

The recommended distance between the heater and the rest of the system elements should be no less than the diagonal of the heater, i.e. the distance from corner to corner in its air duct part. Duct heaters are designed for a minimum air flow speed of 1.5 m/s and the maximum operating temperature of the exhaust air is 40°C. If a fan speed controller is used, it is necessary to ensure a minimum air flow through the heater.

It is prohibited to supply power voltage to the heater when the fan is turned off.

For proper and safe operation of heaters, it is recommended to use an automation system that provides comprehensive control and protection:

  • automatic adjustment of power and air heating temperature,
  • monitoring filter status using a differential pressure sensor
  • blocking the power supply to the heater in case of a stop of the supply fan or a decrease in the air flow rate, as well as when the built-in overheating protection thermostats are triggered
  • shutdown ventilation systems with purging of heating elements of the heater.

Technical characteristics

< tr>
Parameter Value
Minimum air flow, m3/h

1100
Current, A

21.7

Voltage< /strong>, B

400
Power, W 15000
Number of heating elements x power, kW 3x5.0
Weight, kg 9.4

Dimensions

'Drawing

Dimensions B B1 B2 B3 H H1 H2 L
mm 600 620 640 740 300 320 340 200

'Temperature

Diagram of pressure drop with increasing air flow through the heater

'Pressure

Documentation

'Passport

Characteristic
Heater power 15 kW
The size of the rectangular channel 600x300 mm

The product will be manufactured after making a payment or a 50% advance payment.

Online payment methods: Bizum, Apple Pay, Mastercard, Visa.

For payments to the bank account of VIP Ventanas SL company: SWIFT, SEPA.

It is possible to make the payment without VAT if the product is delivered outside of Spain.

Delivery is carried out by the company's own transportation or delivery service.

Write a review

Please login or register to review